Specify IXPE foam underlayment by checking density and compression data, reading acoustic results against the tested floor-ceiling assembly, confirming the moisture-control construction, and agreeing usable roll dimensions. For distributors, flooring brands and project buyers, these details make quotations comparable and reduce approval errors.
UTOP publishes density options of 100–200 kg/m³, thicknesses of 1–3 mm and a listed roll length of 400 m with customizable width. For the selected IXPE foam underlayment, request the current datasheet, reports and approved sample. Confirm which options match your intended flooring, production process and order. Identify loose-roll supply versus factory-attached backing early because their production requirements differ.
Density measures mass per volume; foam structure describes the material’s cells. IXPE is closed-cell, cross-linked polyethylene foam; density alone does not establish resistance to long-term loading.
Compare density together with thickness tolerance, compression behavior and recovery data. Ask whether density describes the foam itself or a laminated construction including film.
For example, 100 kg/m³ foam at 1 mm thickness weighs 0.10 kg/m² before coatings. This checks specification consistency; it does not predict acoustic performance.
Choose an IXPE foam underlayment using the flooring manufacturer’s support requirements and relevant test evidence, rather than selecting the highest density automatically.
IIC rates impact-sound insulation, while STC rates airborne-sound insulation of the tested assembly. They address different sound paths and are not interchangeable.
UTOP’s page lists IIC 67, STC 69 and 22 dB impact-sound reduction. Compare these separate figures using their supporting reports:
| Published figure | What it describes | What buyers must compare |
|---|---|---|
| IIC 67 | Impact-insulation class | Floor finish, slab, underlay and ceiling construction |
| STC 69 | Airborne sound-transmission class | Complete tested partition or floor-ceiling assembly |
| 22 dB reduction | Reported change in impact sound | Test method, reference assembly and measurement conditions |
ASTM E989 explains impact-noise classifications; ASTM E413 addresses sound-insulation ratings. IIC and STC are class ratings, not standalone decibel reductions.
Request the report number, specimen details and test configuration. Check whether the tested slab and ceiling match the project assembly. An underlay rating alone does not establish project compliance.
Water-vapor resistance describes moisture passage through a material under stated test conditions. Closed-cell foam structure alone does not establish the performance of seams, edges or an installed vapor-control system.
Confirm film type, film thickness, water-vapor test results, units, test conditions and seam-sealing instructions. ASTM E96/E96M provides methods for measuring water-vapor transmission; compare results obtained under equivalent conditions.
For SPC flooring, confirm permitted underlay thickness and whether additional cushioning is approved when a pad is already attached. Follow the flooring supplier’s concrete-moisture testing and mitigation requirements.
Roll size defines the supplied length, width and nominal area, while usable coverage also depends on cuts, overlaps and installation layout. UTOP lists 400 m per roll with customizable width.
At an illustrative width of 1 m, a 400 m roll contains 400 m² before allowances. Confirm whether the format suits installation, conversion or factory lamination.
Agree thickness and density tolerances, film construction, winding direction, core size, outer diameter, net/gross weight and labeling. Retain an approved sample and written acceptance criteria. Confirm packing dimensions for logistics quotations.
An approved IXPE specification links material data, test evidence and supply requirements. Density, IIC/STC and roll dimensions answer different procurement questions; assess them together.
Send UTOP your flooring construction, intended application, acoustic target, moisture-control requirements and roll format to request IXPE technical data and custom specification support. Ask for the proposed datasheet, relevant reports and sample confirmation before approving bulk production.
IXPE specifications define material, performance and delivery requirements.
IXPE is irradiated cross-linked polyethylene foam used beneath flooring or as attached backing. For “IXPE flooring” quotations, identify the floor construction and IXPE pad separately.
No. Select density alongside compression performance, thickness and flooring compatibility. Density alone does not establish suitability.
No. They describe different acoustic properties. Neither their sum nor either figure alone represents a decibel reduction supplied by the foam.
That depends on the tested construction and flooring instructions. Verify vapor-transmission data, film and sealed seams before making that decision.
Use an additional layer only when the flooring manufacturer approves the complete build-up and thickness.
Specify density, thickness, tolerances, film, roll dimensions, packing, test-report references and sample requirements. State whether the order is for loose underlay or attached backing.